The meter has an auto-ranging function and an auto-off function, which helps conserve battery life when the device is not in use. The buzzer Continuity alerts the user when resistance is less than 40Ω. The PA900 also has an automatic data hold function, which freezes the current reading for easy recording. MAX/MIN function allows the user to keep track of higher readings and lower, while the backlit display ensures easy reading in low light conditions. The device also features a low battery display, indicating when it is time to replace the batteries.
Features –
- Display 6000 Counts
- Jaw Opening Ø26mm/1.0″
- Auto range
- Auto Power Off
- Dual Display
- Continuity Buzzer <40Ω
- Data Auto hold
- MAX/MIN
- Display Backlight
- Low Battery Display
Specifications | Range | Resolution | Accuracy |
---|---|---|---|
DC Voltage | 6V/60V/600V | 0.01V/0.1V/1V | ±(0.5%+3) |
AC Voltage | 6V/60V/600V | 0.01V/0.1V/1V | ±(0.8%+5) |
AC Current | 2A/20A/200A | 0.01A/0.01A/0.1A | ±(2.5%+8) |
600A | 1A | ±(3.0%+10) | |
Resistance | 2kΩ/20kΩ/200kΩ/2MΩ | 0.001kΩ/0.01kΩ/0.1kΩ/0.001MΩ | ±(0.8%+3) |
10MΩ | 0.01MΩ | ±(1.0%+5) | |
Frequency (Clamp) | 60Hz/600/3kHz | 0.1Hz/1Hz/10Hz | ±(1.0%+5) |
Frequency (Plug) | 60Hz/600/3kHz | 0.1Hz/1Hz/10Hz | ±(1.0%+5) |
Duty Cycle | 10%~90% | 1% | ±2.0% |